LCD module FRM01 1 channel multifunction relay module / delay cycle / timer / Auto-lock / 5V, 12V 24

rating

Product descriptionMultifunctional Frm01 relay module (5 V, 12 V, 24 V optional)The products photog..

  • 1.SYP 160,023.SYP

  • Brand: ATC
  • Product Code:18005018
  • Availability:Pre-Order

Storage Code: CC0302X0403

Product description
Multifunctional Frm01 relay module (5 V, 12 V, 24 V optional)

The products photographed need how many V
Please, give us a message.
Frm02 Type 1 channel multifunction relay control module, designed for the variety of different user needs design, use the microcontrollers as a master unit, activate 18 kinds of functions, and can according to user demand, made to measure and add another function specific.
Power relay use module of genuine quality, high power High presosttransistor, red, blue signal lights, military-grade duplex PCB board, design considers a broad and stable performance, can be widely used in a variety of control types power.
Features:
1. Availability 1hannel input output control, each channel can configure respectively 18 types of function, meet more application requirements;
2. With anti-reverse power supply, it will not be because the wrong power supply damage module;
3. Using high-quality high-power power modules, more stable stable system;
4. At least you can set 0.1 seconds of synchronization, synchronization accuracy better than 0.01 seconds;
5. increase the automatic characteristics of energy saving, the user can set voluntarily;
6. All configuration options, can save auto, configure the electricity of the non-lost content.
A module features
User can by buttons and screen, select the following 18 types of function one, can set and save parameter characteristics, and can see the current function of the parameter, set time parameters minimum0.1seconds adjustable, EXACT ACCURACY of 0.01 seconds, in particular to configure the operating instructions, purchase the electronic version to sellers request electronic version "frm02 user s manual."
Hot light: function 1-8 on automatic start, function 9-18 needs a high-level pulse signal trigger, (high continuous level no shorter 20 ms, hereafter the same) function 9 is a mode of self-lock, Function 10 is a level control mode.
Function 1:
Time play: After the power delay T1 time relays t1 in 0.1 second-270 hours between adjustable, give the CH1 interface a high-level pulse signal, repeat once functions; or several times
Function 2:
Disconnection of the disconnection time: in the power time relays pull, T1 in 0.1 second-270 hours between adjustable, give the CH1 interface a high-level pulse signal, repeat once functions; or several times .
Function 3:
Disconnection of time of configuration of new disconnection: the relays of power-in the rear not pull, delay time T1 arrivals rear Relays pull; pull time T2 rear arrivals Relays disconnection, delay time T1 and T2 in 0.1 second-270 hours between adjustable, give CH1 interface a high-level pulse signal, repeat once functions; or several times
Function 4:
Configuration of disconnect time again pull: Relays power-on immediately pull, delay time T1 arrivals rear relays Disconnection; Disconnection time delay time T1 and T2 in 0.1 seconds-270 hours between adjustable, give CH1 interface a high-level pulse signal, the previous functions repeat once; or repeat several times .
Function 5:
Infinite loop configuration time mode 1: power on, relays first do not pull delay time T1 rear arrivals Relays pull; pull time T2 rear arrivals Relays disconnected, then repeated the previous state, delay time T1 and T2 in 0.1 seconds-270 hours between adjustable, give CH1 interface a high-level pulse signal, you can reset these functions;
Function 6:
Infinite loop configuration time mode 2: the power relays-over the rear relays immediately delay time T1 arrivals rear disconnect relays; Disconnection time T2 after the relay arrival then also repeat the previous state, delay time T1 and T2 in 0.1 second-270h between adjustable, give the CH1 interface a high level pulse signal, you can restart these functions;
Function 7:
Time mode setting of limited cycle 1: Power rear relays first do not pull, delay time T1 rear arrivals Relays pull; pull time T2 rear arrivals Relays disconnection, then also repeat NX times the previous state, this time T1 and T2 in 0.1 seconds-9999 seconds between adjustable, NX cycle frequency in1-9999 secondary between adjustable, give CH1 interface a pulse signal high level, you can restart these functions;
Function 8:
Limited cycle time time Mode 2: power on, relays immediately pull, delay time T1 arrivals rear relays Disconnection; Disconnection time then also repeat NX times the previous state, this time T1 and T2 in 0.1 seconds-9999 seconds between adjustable, NX cycle frequency in1-9999 secondary between adjustable, give CH1 interface a high-level pulse signal, can restart these functions;
Function 9:
Self-locking relay mode: give the relays the CH1 interface a high-level pulse signal, the relays pull, once again, disconnect the high-level pulse signal relays.
Function 10:
Trigger relay mode: contain delay disconnect characteristics, power rear relays no action, give the CH1 interface a high level pulse signal, relays immediately pull, the CH1 signal disappears back, the relays keep pulling, when the Traction relays T1 reach the rear disconnection relays, this time T1 in 0 seconds-270 hours between adjustable.
Note: This function, in the case T1 established for 0 seconds, becomes: CH1 have high level signal relays, without signal, immediately disconnect.
Function 11:
Trigger time activation: Power-on relays without action, give the CH1 interface a high-level pulse signal, delay T1 time relays t1 at 0.1 second-270 hours between adjustable, repeat give CH1 interface a pulse signal from high level, repeat once functions; or several times .
Function 12:
Disconnection of the disconnection time of the assembly: power-on relays Without action, give the CH1 interface a high-level pulse signal, traction relays, delay T1 disconnection time relays, t1 in 0.1 second-270 hours between adjustable, Repeat give CH1 interface a high level pulse signal, repeat functions once, or several times.
Function 13:
Closing closing time of trip and disconnection: Relays power-on without action, give CH1 interface a high-level pulse signal, delay time T1 arrivals rear relays pull; disconnection of time T2 disconnection of the rear relays, delay time T1 and T2 in 0.1 seconds-270 hours between adjustable, repeat give the CH1 interface a high-level pulse signal, repeat once functions; or several times.
Function 14:
Activation of the disconnection time give the CH1 interface a high-level pulse signal, relays immediately pull, delay time T1 arrivals rear relays Disconnection; Disconnection time delay time T1 and T2 in 0.1 seconds-270 hours between adjustable, repeat give CH1 interface a high-level pulse signal, repeat once functions; or several times.
Function 15:
Unlimited cycle configuration time mode 1: Power-on relays No action, give CH1 interface a high-level pulse signal, delay time T1 arrivals rear relays pull; pull the time T2 arrivals the disconnect back relays, then also repeat the previous state, delay time T1 and T2 in 0.1 seconds-270 hours between adjustable, repeat the CH1 interface a high-level pulse signal, you can re-start the previous characteristics;
Function 16:
Infinite loop synchronization mode 2: after the power relay does not act, the interface to a high-level pulse signal CH1, immediately pull the relay, the delay time T1 after arrival; out of time T2 after reaching the relay, then repeat the previous state, delay time between T1 and T2 in 0.1 seconds-270 adjustable hours, repeat the CH1 interfaces to a high-level pulse signal, we can resume these functions;
Features 17:
Finite loop synchronization mode 1: After the power relay does not act, a high-level interface to the pulse pulse signal of CH1 time t1 after the arrival relay; take off the relay after T2 arrives, and then repeat the previous state NX in this time between T1 and T2 in 0.1 seconds-9999 seconds adjustable, NX cycles adjustable between 1 and 9999 times, repeat the CH1 interfaces to a pulse signal high level, we can resume these functions;
Function 18:
Finite loop synchronization mode 2: after the power relay does not act, the interface to a high-level pulse signal CH1, immediately pull the relay, the delay time T1 after arrival; out of time T2 after reaching the relay, then repeat NX times more states, this time between T1 and T2 in 0.1 seconds-9999 seconds adjustable, NX cycles adjustable between 1 and 9999 times, repeating a high-level pulse interface CH1, can start new features;
Two electrical parameters
Operating voltage: DC 5 V, 12 V, 24 V three options (must not exceed the rated voltage of +/- 10%)
Current: 5 V when less than 180ma (when the relay does not operate less than 15ma, turn off the screen less than 3ma)
12 V is less than 90ma (when the relay does not operate less than 15ma, turn off the screen less than 3ma)
When 24 V is less than 60ma (when the relay does not operate less than 15ma, turn off the screen less than 3ma)
Operating temperature: recommended -20 ° -60 ° (maximum operating temperature range -30 ° -70 °)
Load capacity: Normally open relay maximum load capacity: DC 0-30 V / 10a, AC 0-250 V / 10A
Maximum load capacity: DC 0-28 V / 10a AC 0-125 V / 10A
Three module interface
Module voltage / signal inputs: A 3-wire interface, all interfaces are terminal, easy to use
1, DC +: DC Power positive
2, DC-: negative DC power supply
3, CH1: Input signal detection interface 1
4, CH2: Input signal detection interface 2